Page 19
address in blocks of three followed by the ENTER key. Once all four blocks are entered the following message will be displayed: HIT ENTER IF DEFAULT ROUTE REQUIRED If a Router or Gateway is required press the ENTER key. The following message will be displayed: ROUTER IP ADDRESS ###. ###. ###. ###. _ _ _ This is the system Router used for directing Internet traffic among a variety of Hosts. (See your network administrator for assignment.) Enter the numeric Router or Gateway address in blocks of three followed by the ENTER key. The next message allows an enablement of the Broadcast Receive command. If this function is disabled, all broadcast packets will be ignored by the terminal. HIT ENTER TO ENABLE BROADCAST RECEIVE Disabling Broadcast Receive may be accomplished by pressing the CLEAR key (recommended for networks with heavy traffic). Upon disablement, only devices connected to the same network mask will be able to “Ping” terminals. The Application Acknowledgement message assures that the Host has received the last transaction, which enhances data integrity by affirming that the transaction has not been held up in a router/gateway or lost. The terminal will display the following: HIT ENTER TO ENABLE APPLICATION ACK Application Acknowledgement may be disabled by pressing the CLEAR key. The next message, TCP/IP Watchdog, provides a “soft restart” if the connected terminal has not communicated with the Host for approximately ten- (10) minutes. The terminal will display the following message: HIT ENTER TO ENABLE TCP/IP WATCHDOG Pressing the CLEAR key will disable TCP/IP Watchdog. The following message allows the Ethernet communication connection. ENETADD=XXXXXXXXXXXXHIT ENTER TO CONNECT The XXXXXXXXXXXX represents the unique Ethernet address programmed into the EPROM by the factory. If a Router is not required, press the CLEAR key. The following message will be displayed: ENETADD=XXXXXXXXXXXXHIT ENTER TO CONNECT The XXXXXXXXXXXX represents the unique Ethernet address programmed into the EPROM by the factory. Press the ENTER key or the CLEAR key if connection is not required. The terminal will briefly display an initializing message followed by: CONNECTING TO SERVER If the connection to the server was successful the message "CONNECTION COMPLETE" is displayed. If the connection to the server was not successful "CONNECTION FAILED!!" will appear. Then "HIT ENTER TO CONNECT". Press the ENTER key. The terminal will display the following: CLOSING CONNECTION BEFORE RECONNECTION 16 MANU4000-01(02)
Page 20
Followed by the brief initializing message: CONNECTING TO SERVER At this time, the terminal will either complete the connection or fail. If a connection failure occurs after numerous attempts, see the troubleshooting section of this manual for further assistance. This completes the ACCU-RATE ETHERNET test
Downloading the Series 4000 The Series 4000 terminal, when used with the standard Time and Attendance "C" application, can be downloaded with employee names, badge numbers, schedules, etc. These download commands and others are explained in the ATS DATA TRAKER command set manual. For further information refer to this manual.
17 MANU4000-01(02)
Page 21
MAINTENANCE
The Series 4000 is a maintenance-free data collection device. The only required procedure is periodic cleaning of the badge reader. To clean the badge reader, swipe a pre-moistened (isopropyl alcohol) cleaning card through the reader several times. Low usage readers should be cleaned monthly. High usage readers should be cleaned weekly.
18 MANU4000-01(02)
Page 22
TROUBLESHOOTING GUIDE
Problem: Terminal does not power up, the display and none of the status LEDs are lit. Possible cause: No DC power applied Solution: Ensure primary side of DC power pack assembly is plugged into a live AC outlet. Ensure secondary side of DC power pack assembly is plugged into the Time and Data Collection Terminal (DCT). Solution: Test the outlet by plugging in another appliance. Solution: If all else fails, replace the power pack assembly. NOTE: If the battery backup option is installed, the terminal will operate for approximately 1.5-hours when the primary voltage source is lost. After this, the terminal will power off. The yellow indicator light, located on the front of the terminal, will illuminate while operating in the battery backup mode. Problem: Yellow Low Power indicator is lit. Possible cause: Low DC power is attached. Solution: Check the AC voltage. Solution: Replace 12-volt DC power pack. Possible cause: Terminal does not go blank after unplugging the battery connector. Solution: Unplug and replace the power pack assembly. Problem: Terminal is not communicating with Host. Possible cause: The terminal TEST/USE switch is in the TEST position Solution: Place the TEST/USE switch is in the USE position. Possible cause: DCT to Host communication cable is defective or unplugged on either end. Solution: Verify cable is tested and plugged into both ends. (Ensure cable termination guidelines and lengths are observed.) Solution: Ensure the application package is loaded and running on the host. Possible cause: Communication parameters for the DCT do not match those of the Host. Solution: Refer to the ACCU-RATE test and diagnostics section for set-up directions. Problem: DCT does not accept badge data. Possible cause: Bar code badge is not manufactured to proper specification. Solution: Refer to vendor’s specifications for manufacturing criteria. Possible cause: Badge is being swiped in the wrong direction. 19 MANU4000-01(02)
Page 23
Solution: Ensure media faces to the right (away from the keypad). Possible cause: Badge reader needs cleaning. Solution: Swipe a pre-moistened (isopropyl alcohol) cleaning card through the reader several times. Possible cause: Badge number does not exist in validation file. Solution: See Supervisor NOTE: If all solutions fail try reading badge in the ACCU-RATE Test Mode. Problem: Terminal does not accept keypad input. Possible cause: Keyed data does not exist in validation file Solution: See Supervisor Possible cause: Keypad connector is unplugged. Solution: Test keypad in the ACCU-RATE Test Mode. If all solutions have been explored and the problem still exists, contact the Accu-Time Product Service Department at (860) 870-5000 during normal working hours 9 AM to 5 PM- Monday through Friday. Prior to contacting AccuTime, please have available the serial number and, if possible, the configuration number of the product. NOTE: The DCT has no user serviceable parts. The Accu-Time terminal must be operated within the parameters included in this manual. Any operation performed contrary to these parameters will void the warranty
20 MANU4000-01(02)
Page 24
ETHERNET TROUBLESHOOTING GUIDE
POWER RELATED Problem: The terminal display is blank (no characters or backlight). Possible cause: The primary of the power pack assembly is not plugged into an AC-wall outlet. Solution: Check the outlet, both ends of the power pack, and if it is a 12VDC power pack. Solution: If all else fails, replace the power pack. NOTE: If the battery backup option is installed, the terminal will operate for approximately 1.5-hours when the primary voltage source is lost. After this, the terminal will power off. The yellow indicator light, located on the front of the terminal, will illuminate prior to the terminal blanking out. Problem: The low power (yellow) indicator LED is activated. Possible cause: Outlet or power pack problem. Solution: Perform the above solution if the terminal display goes blank upon removal of the battery connector. COMMUNICATION RELATED Problem: The terminal is not communicating with the host. Possible cause: Communication parameters were not previously set. Solution: Place terminal in Test Mode and step through ACCU-RATE Test procedures. The network administrator would provide the following: IP address to be assigned to the terminal • IP address of the host to which the terminal can connect • Network Mask (example 255.255.255.0) • Gateway or Router address (if required) • Solution: If parameters are set, place terminal in Use Mode and perform a "ping" on the terminal. Solution: Verify activity of LEDs located on the bottom of the terminal. Solution: Verify that the cable is plugged into both ends (terminal and hub) and terminated to the appropriate eight- (8) position modular connector. Solution: Verify that the single segment cable length is equal or less than the specified 328 feet. The cable should also be a 10-base-T category 5, twisted pair high-speed data transmission cable with both ends properly crimped. Solution: Insure application package is loaded and running on the host. Ethernet diagnostic LEDs: Yellow: terminal is BUSY processing Green: terminal is LINKED to host Yellow: terminal data is being RECEIVED Red: terminal data is being TRANSMITTED Problem: A previously working terminal now is not operational. 21 MANU4000-01(02)
Page 25
Possible cause: TEST/USE switch is not in the Use position. Solution: Place TEST/USE switch in Use position. Possible cause: Cables not plugged in or host application software not operational. Solution: Insure that all connections are made and that the host software application is functional. If possible, take a known working terminal, re-address it for this particular node and determine if the problem is related to the terminal, installation or host.
If neither the standard nor Ethernet troubleshooting guide is of any help, please contact the Accu-Time Product Service Center, (860) 870-5000, for further assistance.
22 MANU4000-01(02)
Page 26
FCC Statement
This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: * * *
Reorient or relocate the receiving antenna. Increase the distance between the time clock and the receiver. Connect the equipment into an outlet on a circuit different from that which the receiver is connected.
FCC Warning: To assure continued FCC emission limit compliance, the user must use only the recommended shielded interfacing cable when connecting to a host computer. Also, any unauthorized changes or modifications to this equipment would void the user authority to operate this device.
23 MANU4000-01(02)
Page 27
MANU4000-01(02)
24
2000INST.DRW
"B"
"A"
"A"
The hole pattern labeled "B" may accomodate power and communication wiring.
When securing to a flat wall, use the mounting-hole pattern, labeled "A".
"A"
4000 SERIES MOUNTING TEMPLATE