For the Accu-Time Series 4000

Page 1

SERIES 4000 TIME AND DATA COLLECTION TERMINAL

Accu-Time Systems, Inc. 420 Somers Road, Ellington, CT 06029 Tel: (860) 870-5000 Fax: (860) 872-1511 Web Site: www.accu-time.com

Page 2

Copyright 2000 Accu-Time Systems, Inc. Accu-Time is a registered trademark of Accu-Time Systems, Inc. The material contained in this manual is subject to change. No part of this manual may be reproduced or distributed in any form or by any means, or stored in any database or retrieval system, without Accu-Time’s prior written permission. Accu-Time Systems, Inc. makes no warranty of any kind including, but not limited to, any implied warranties of merchantability, and fitness for a particular purpose in regard to this manual.

All Rights Reserved. Printed in the USA.

Page 3

ACCU-TIME SERIES 4000

TABLE OF CONTENTS

Introduction Features Specifications Installation

1 2 3 4

ACCU-RATE Diagnostics Ethernet Setup and Testing

9 15

Maintenance Troubleshooting Guide Ethernet Troubleshooting Guide

18 19 21

MANU4000-01(02)

Page 4

INTRODUCTION The Accu-Time Series 4000 is a true “C” programmable Time and Data Collection Terminal. Highly versatile for incorporation into any time or data collection environment, the Series 4000 offers a large user memory base of up to 768K. In addition to operating in standard EIA communication formats, the Series 4000 is TCP/IP Ethernet 10-base-T compatible. Among the many features of the Series 4000 are: Multi-Media: Can support most standard bar code formats including UPCA, 128, 3 of 9, 2 of 5, Interleave 2 of 5 and more, as well as IATA Track I and ABA Track II magnetic stripe input (program dependent). Flexibility: The Series 4000 can act as a stand alone time station or as part of a local or wide area network. The terminal can also interface with virtually any host hardware or software platform. Custom Applications: Custom programs and programmable function keys can provide users with the flexibility to create a variety of options. Reliability: A Real Time Clock (RTC) provides 12 or 24 hour time formats with quartz precision. An optional non-interruptible power supply (UPS) provides terminal operation for up to 1.5 hours during power outages. Data storage will be preserved for up to 4 days with the memory backup system. Durability: Environmental enclosure protects circuitry from environmental conditions such as extreme temperatures and airborne dust. Versatility, Reliability and Affordability in a state-of-the-art ergonomically designed terminal and backed by the ACCUTEAM.

1 MANU4000-01(02)

Page 5

FEATURES

•

Single or multi-clock environments on a variety of host platforms with application programs integrating the ATS DATA TRAKER family of modules.

•

128K Byte capacitor backed memory base, expandable to 768K

•

512K Byte Flash memory (optional)

•

TCP/IP Ethernet 10-base-T compatible (802.3)

•

EIA Standard RS232/RS485, jumper selectable communication.

•

1200/2400, 9600, 19.2K-Baud modem operation

•

On-board ACCU-RATE terminal set-up and diagnostics package.

•

Dual tone audible annunciator

•

Custom keypad legends with software defined function keys

•

Large 20 key tactile 4x5 matrix keypad

•

4 Line x 20 Character liquid crystal backlit display (optional)

• + •

4 Line x 20 Character Vacuum Fluorescent display (optional)

•

Integrated or External Bar Code slot reader

•

Integrated magnetic slot reader

•

DI/DO port

•

Digital bar code wand port

•

Supports external wand emulation bar code laser and CCD readers

•

Low voltage power source locally or remotely supplied

•

Non-interruptible power source with on-board charger

•

Die cast aluminum housing with key-lockable, tamper resistant base assembly

•

CE Mark and FCC part 15 Certified

Diagnostic LEDs for Ethernet - 2 yellows, 1 green, and 1 red described in Troubleshooting Guide.

2 MANU4000-01(02)

Page 6

SPECIFICATIONS

Display:

4 Line x 20 Character backlit super-twist LCD (optional) 4 Line x 20 Character Vacuum Fluorescent (optional)

Clock:

12 or 24 hour-format--USA or International (quartz precision) Time stamp of data transactions

Indicators:

Yellow LED Low Power indicator Two programmable LED indicators, RED and GREEN Diagnostic LEDs for Ethernet: Yellow = busy Green = linked Yellow = receive Red = Transmit

Memory:

128K Byte of capacitor backed memory Expandable to 768K Byte 512K Byte Flash memory (optional)

Programming:

ATS DATA TRAKER modules, “C” programming language or third party custom application packages.

Interface:

TCP/IP Ethernet 10-base-T (802.3) EIA Standard RS232/RS485 jumper selectable Standard AT Command set for internal 12/2400, 9600, 19.K-Baud Modem operation. Digital bar code wand input port

Enclosure:

Die cast aluminum housing with key-lockable base assembly

Power:

+10 to 17 VDC (+12 VDC @ 470 milliamps Nominal) Local, remote or centrally powered Non-interruptible power source with charger (optional)

Environment:

Operation: 32° to 110° F (0° to 43° C)

Certification:

CE Mark Certified (CE, RE, ESD, RS and CS), FCC part 15

Physical:

9.75” wide x 7.25” high x 3.8” deep. Weight: 6 LBS 24.77cm wide x 18.42cm high x 9.65cm deep. Weight: 2.72kg

Accessories:

Integrated or External Optical Bar Code slot readers Integrated magnetic slot readers Digital Bar Code Wands Solid State or Dry Contact relay modules Serial Interface Printer Port External wand emulation bar code laser CCD readers

3 MANU4000-01(02)

Page 7

INSTALLATION

GENERAL INSTALLATION GUIDELINES

Environment Although the Series 4000 Time and Data Collection Terminal is a durable industrial-grade device, which will endure harsh environments, it never the less is an electronic device. Environmental constraints exist and care should be given when selecting a location for installing and operating the Series 4000. The ATS terminal is designed to operate indoors. Exposure to outdoor elements such as rain or snow will not only void the manufacturer warranty, but may cause damage to the device. Select a location, which has adequate lighting and accessibility to operate the terminal safely. Operating parameters Accu-Time recommends the Series 4000 operate in an ambient temperature range of between 32° and 110° Fahrenheit. Non-condensing humidity should be less than 95%. The terminal should be mounted on a vibration free surface. The RS232 Series 4000 must be located no greater than fifty (50) wire-feet from the host computer. EIA standards for RS232 protocol data transmission dictate this cable distance. Exceeding this requirement greatly increases the chances for continual data re-transmission, which may never be acknowledged. The total cable length of the combined RS485 terminal/host drop points should not exceed five thousand (5000) wirefeet. EIA standards for RS485 protocol data transmission dictate this cable distance. Exceeding this requirement greatly increases the chances for continual data re-transmission, which may never be acknowledged. The Ethernet Series 4000 may be located at any point within a TCP/IP Ethernet 10-BASE-T network, providing the single segment length from the network hub does not exceed three hundred and twenty-eight (328) wire-feet. A typical topology for the Series 4000 in an Ethernet 10-base -T network is a star configuration.

4 MANU4000-01(02)

Page 8

INSTALLATION

Base Locate a flat wall surface to accommodate the Series 4000. With terminal power being supplied locally, insure that a conventional 110VAC-wall outlet, 220VAC in Europe and other areas, (check local electrical code requirements) is dedicated to accept the Series 4000 12VDC power pack assembly. The outlet should be no further than four (4) feet from the terminal. With the supplied terminal mounting template, prepare the wall to accommodate mounting hardware (customer provided). Typical mounting height is forty-eight inches from floor to the terminal display (Compliant to the Americans with Disabilities Act). Observe OSHA and/or local safety codes when operating tools during all phases of installation. Attach the terminal wall mount to the flat wall surface. Select and remove one of the perforated knockouts on the wall mount, which will accommodate the data transmission and 12VDC power pack cable assemblies.

RS232 Installation For RS232 applications, ATS recommends using its modular telephone type data cable. This eight- (8) conductor shielded flat cable has RJ-45 modular plugs on each end. The fifty- (50) foot cable may run along side base-moldings, walls, overheads, or in hostile environments through conduit tubing. One end of the cable terminates into the Series 4000 communication port while the other terminates into the host computer’s serial port via an ATS RS232 Communication Adapter.

12 VDC POWER SUPPLY

Pin # 1 2 3 4 5 6 7 8

ACCU-TIME SYSTEMS ELLINGTON, CT

LOW

INVALID

VALID

POWER

1 2

3

F1

F5

4 5

6

F2

F6

7 8

9

F3

F7

ENTER

F4

F8

CLEAR

0

Description Earth Ground Receive Transmit N/C N/C Ground +VDC Ground

NOTE: Pinouts are referenced to the terminal TO HOST

COMM ADAPTER DB25-RJ45 W/PWR

5 MANU4000-01(02)

Page 9

RS485 Installation For RS485 communication applications, ATS recommends using a data transmission cable that adheres to the following specifications: Five conductor shielded 24-gage wire with a drain. The impedance of the cable should be 100 Ohms. The capacitance should be 12 pico-farads per foot. The jacket of the cable is typically PVC or Plenum material. NOTE: If the host is not equipped with an RS485 communication port, an ATS RS232/485 Converter with 12 volt power pack assembly is required to convert the terminal communication lines to Host RS232 levels. The host output of the RS232/485 converter plugs directly into the ATS RS232 Communication Adapter. RS485 allows for the Series 4000 to be used in multi-dropped networks. Thirty-two (32) terminals can be supported on a single host communication port. The use of ATS Series 1000 Network Controllers allow up to two hundred and fifty-six (256) terminals on a single host communication port. 1

2

3

5

4

6

8

P.GND

+VDC

P.GND

6

7

8

P.GND

+VDC

P.GND

E.GND

COMM

7

6

7

8

Pin # 1 2 3 4 5 6 7 8

Network Trunk Cable 1

2

3

5

4

E.GND

COMM

1

2

3

4

5

P.GND

+VDC

P.GND

E.GND

COMM

DC POWER JP2

JP1

NC

JP3

DROP 1

DROP 2

DROP 3

NOTE: Pinouts are referenced to the terminal

JP4 NC

NO

DROP 4

Description Earth Ground DI DO + DO DI + Ground +VDC Ground

NO

E.GND

12 VDC POWER SUPPLY

RS-232 TO RS-485 CONVERTER

NETWORK CONTINUED

TO HOST

COMM ADAPTER DB25-RJ45 W/PWR

12 VDC POWER SUPPLY

ACCU-TIME SYSTEMS

ACCU-TIME SYSTEMS

ELLINGTON, CT

LOW

INVALID

ELLINGTON, CT

VALID

LOW

POWER

VALID

POWER

1 2 3

F1

F5

1 2 3

F1

F5

4 5 6

F2

F6

4 5 6

F2

F6

7 8 9

F3

F7

7 8 9

F3

F7

0 ENTER F4

F8

0 ENTER F4

F8

CLEAR

CLEAR

6 MANU4000-01(02)

INVALID

12 VDC POWER SUPPLY