For the Accu-Time Series 2000
Page 1
SERIES 2000 TIME AND DATA COLLECTION TERMINAL
Accu-Time Systems, Inc. 420 Somers Road, Ellington, CT 06029 Tel: (860) 870-5000 Fax: (860) 872-1511 Web Site: www.accu-time.com
Page 2
Copyright 1992 Accu-Time Systems, Inc., Fourth Printing 2000. Accu-Time is a registered trademark of Accu-Time Systems, Inc. The material contained in this manual is subject to change. No part of this manual may be reproduced or distributed in any form or by any means, or stored in any database or retrieval system, without Accu-Time’s prior written permission. Accu-Time Systems, Inc. makes no warranty of any kind including, but not limited to, any implied warranties of merchantability, and fitness for a particular purpose in regard to this manual.
All Rights Reserved. Printed in the USA.
Page 3
ACCU-TIME SERIES 2000
TABLE OF CONTENTS
Introduction Features Specifications Installation
1 2 3 4
ACCU-RATE Diagnostics Ethernet Setup and Testing
9 14
Maintenance Troubleshooting Guide Ethernet Troubleshooting Guide
17 18 20
MANU2000-01(04)
Page 4
INTRODUCTION
The Accu-Time Series 2000 is a true “C” programmable Time and Data Collection Terminal. Designed to be used in any time or data collection environment, the Series 2000 offers a large user memory base of up to 768K for file validation, local editing and scheduling functions. In addition to operating in standard EIA communication formats, the Series 2000 is also TCP/IP ETHERNET 10-base-T compatible. Among the many features of the Series 2000 are: Multi-Media: Can support most standard bar code formats including UPC, 128, 39, 2/5, I2/5 and more, as well as IATA Track I and ABA Track II magnetic stripe input. Flexibility: The Series 2000 can act as a stand alone time station or as part of a local or wide area network. The terminal can also interface with virtually any host hardware or software platform. Custom Applications: Custom programs and programmable function keys can provide users with the flexibility to create a variety of options. Reliability: A Real Time Clock (RTC) provides 12 or 24 hour time formats with quartz precision. An optional non-interruptible power supply (UPS) provides terminal operation for up to 4 hours during power outages. Data storage will be preserved for up to 4 days with the memory backup system. Durability: Environmental enclosure protects circuitry from environmental conditions such as extreme temperatures and airborne dust. Versatility, Reliability and Affordability in a state-of-the-art ergonomically designed terminal and backed by the ACCUTEAM.
1 MANU2000-01(04)
Page 5
FEATURES
•
Single or multi-clock environments on a variety of host platforms with application programs integrating the ATS DATA TRAKER family of modules.
•
128K Byte capacitor backed memory base, expandable to 768K
•
TCP/IP ETHERNET 10-base-T compatible (802.3)
•
EIA Standard RS232 or RS485 compatible. 9600/19.2-Baud Modem operation
•
On-board ACCU-RATE terminal set-up and diagnostics package.
•
Dual tone audible annunciator
•
Custom keypad legends with software defined function keys
•
Large 20 key tactile 4x5 matrix keypad
•
2 or 4 Line x 20 Character liquid crystal backlit display
•
Diagnostic LEDs for Ethernet - 2 yellows, 1 green, and 1 red described in Troubleshooting Guide.
•
Integrated or External Bar Code or Magnetic slot readers
•
DI/DO port for access control
•
Optional Printer port
•
Digital Bar Code Wand port
•
Low voltage power source locally or remotely supplied
•
Non-interruptible power source with on-board charger
•
Die cast aluminum housing with steel key-lockable, tamper resistant base assembly
•
CE Mark and FCC part 15 Certified
2 MANU2000-01(04)
Page 6
SPECIFICATIONS
Display:
4 Line x 20 Character backlit super-twist LCD 2 Line x 20 Character Vacuum Fluorescent
Clock:
12 or 24 hour-format-USA or International (quartz precision) Time stamp of data transactions
Indicators:
Yellow LED Low Power indicator Two programmable LED indicators, RED and GREEN Diagnostic LEDs for Ethernet: Yellow = busy Green = linked Yellow = receive Red = Transmit
Memory:
128K Byte of capacitor backed memory (I.e.; 600-employee base-program dependent) Expandable to 768K Byte (Over 2000-employee base - program dependent).
Programming:
ATS DATA TRAKER modules, “C” programming language or third party custom application packages.
Interface:
TCP/IP ETHERNET 10-base-T (802.3) EIA Standard RS232 or RS485 (2 or 4 wire) Standard AT Command set for internal 9600/19.2-Baud Modem operation. DI/DO or Serial Interface Printer port. Digital Bar Code Wand input port.
Enclosure:
Die cast aluminum housing with steel key-lockable base assembly Tamper switch (sends alarm message to host)
Power:
+10 to 17 VDC (+12 VDC @ 250 milliamps Nominal) Local, remote or centrally powered Non-interruptible power source with charger (optional)
Environment:
Operation: 32° to 110° F (0° to 43° C)
Certification:
CE Mark Certified (CE, RE, ESD, RS and CS), FCC part 15
Physical:
9.75” wide x 7.25” high x 3.8” deep. Weight: 6 LBS 24.77cm wide x 18.42cm high x 9.65cm deep. Weight: 2.72kg
Accessories:
Integrated or External Optical Bar Code slot readers Integrated Magnetic slot readers Wiegand and RF ID readers Digital Bar Code Wands Solid State or Dry Contact relay modules Serial Interface Printer Port
3 MANU2000-01(04)
Page 7
INSTALLATION
GENERAL INSTALLATION GUIDELINES
Environment Although the Series 2000 Time and Data Collection Terminal is a durable industrial-grade device, which will endure harsh environments, it never the less is an electronic device. Environmental constraints exist and care should be given when selecting a location for installing and operating the Series 2000. The ATS terminal is designed to operate indoors. Exposure to outdoor elements such as rain or snow will not only void the manufacturer warranty, but may cause damage to the device. Select a location, which has adequate lighting and accessibility to operate the terminal safely. Operating parameters Accu-Time recommends the Series 2000 operate in an ambient temperature range of between 32° and 110° Fahrenheit. Non-condensing humidity should be less than 95%. The terminal should be mounted on a vibration free area. The RS232 Series 2000 must be located no greater than fifty (50) wire-feet from the host computer. EIA standards for RS232 protocol data transmission dictate this cable distance. Exceeding this requirement greatly increases the chances for continual data re-transmission, which may never be acknowledged. The RS485 Series 2000 locally powered must be located no greater than five thousand (5000) wire-feet from the host computer. EIA standards for RS485 protocol data transmission dictate this cable distance. Exceeding this requirement greatly increases the chances for continual data re-transmission, which may never be acknowledged. The ETHERNET Series 2000 may be located at any point within a TCP/IP ETHERNET 10-BASE-T Network, providing the single segment length from the network hub does not exceed three hundred and twenty-eight (328) wirefeet. A typical topography for the Series 2000 in an ETHERNET 10-BASE-T network is a star configuration.
4 MANU2000-01(04)
Page 8
INSTALLATION Base Locate a flat wall surface to accommodate the Series 2000. With terminal power being supplied locally, insure that a conventional 110VAC wall outlet, 220VAC in Europe and other areas, (check local electrical code requirements) is dedicated to accept the Series 2000 12VDC power pack assembly. The outlet should be no further than four (4) feet from the terminal. With the supplied terminal mounting template, prepare the wall to accommodate mounting hardware (customer provided). Typical mounting height is forty-eight inches from floor to the terminal display (Compliant to the Americans with Disabilities Act). Observe OSHA and/or local safety codes when operating tools during all phases of installation. Attach the terminal wall mount to the flat wall surface. Select and remove one of the perforated knockouts on the wall mount, which will accommodate the data transmission and 12VDC power pack cable assemblies. Data Cable For RS232 applications, ATS recommends using its modular telephone type data cable. This eight- (8) conductor shielded flat cable has RJ-45 modular plugs on each end. The fifty (50) foot cable, ATS part number (63-2003-02), may run along side base-moldings, walls, overheads, or in hostile environments through conduit tubing. One end of the cable terminates into the Series 2000 communication port while the other terminates into the host computer’s serial port via an ATS RS232 Communication Adapter.
RS232 INSTALLATION
12 VDC POWER SUPPLY
ACCU-TIME SYSTEMS ELLINGTON, CT
LOW
INVALID
VALID
POWER
1 2
3
F1
F5
4 5
6
F2
F6
7 8
9
F3
F7
ENTER
F4
F8
CLEAR
0
Pin # 1 2 3 4 5 6 7 8
Description Earth Ground Receive Transmit N/C N/C Ground +VDC Ground
NOTE: Pinouts are referenced to the terminal
TO HOST
COMM ADAPTER DB25-RJ45 W/PWR
2kPO.DRW
5 MANU2000-01(04)
Page 9
For RS485 communication applications, ATS recommends using a data transmission cable that adheres to the following specifications: Five conductor shielded 24-gage wire with a drain. The impedance of the cable should be 100 Ohms. The capacitance should be 12 pico-farads per foot. The jacket of the cable is typically either a PVC or Plenum material. (*NOTE* If the host is not equipped with an RS485 port, an ATS RS232/485 Converter with 12 volt power pack assembly will convert the terminal communication lines to RS232 levels. The host output of the RS232/485 Converter plugs directly into the ATS RS232 Communication Adapter.) RS485 allows for the Series 2000 to be used in multi-dropped networks. Thirty-two (32) terminals can be supported on a single host communication port. The use of ATS Series 1000 Network Controllers allow up to five hundred and twelve (512) terminals on a single host communication port.
MULTI-CLOCK RS485 INSTALLATION
1
2
3
5
4
1
2
3
4
5
7
8 P.GND
E.GND
CO M M
6
+VDC
5
4
P.GND
3
+VDC
2
8
P.GND
1
7
P.GND
E.GND
CO M M
6
6
7
8 P.GND
+VDC
P.GND
E.GND
COMM
Pin # 1 2 3 4 5 6 7 8
D C PO W ER JP2
JP1
NC
JP3
D RO P 1
JP4 NC
NO
D RO P 2
DR OP 3
NO
Description Earth Ground DI DO + DO DI + Ground +VDC Ground
E. GN D
D RO P 4
NOTE: Pinouts are referenced to the terminal
12 VDC POWER SUPPLY
RS-232 TO RS-485 CONVERTER
NETWORK CONTINUED
TO HOST
COMM ADAPTER DB25-RJ45 W/PWR
12 VDC POWER SUPPLY LOW
ACCU-TIME SYSTEMS
ACCU-TIME SYSTEMS
ELLINGTON, CT
ELLINGTON, CT
INVALID
VALID
LOW
POWER
VALID
F1
F5
1 2 3
F1
F5
4
5
6
F2
F6
4
5
6
F2
F6
7
8
9
F3
F7
7
8
9
F3
F7
0 ENTER F4
F8
CLEAR
0 ENTER F4
F8
CLEAR
6 MANU2000-01(04)
INVALID
POWER
1 2 3
12 VDC POWER SUPPLY