Manual · Accu-Time
Accu-Time 98-9006-00 Manual
Manual1 pagePDF 81 KB
The page is below, with its text.
Covers · 1 model
The models it covers
From the manual · read page by page
Key facts from this manual
Each line names its page in the PDF.
This is a one-page data sheet for the Accu-Time PN 98-9006-00 Network Junction Box, a branch point for RS485 networks of Accu-Time Data Collection Terminals. It describes the connectors, the 12-volt power input and the jumpers that route power to each drop, and lists general specifications.
- Device type
- RS485 communication adapter and network branch point (Network Junction Box) p. 1
- Signals
- Bi-directional RS485 from multi-dropped Accu-Time Data Collection Terminals and from trunk wiring p. 1
- Connectors
- Four 8-pin modular jacks for direct DCT inputs; three 8-pin terminal block connectors for drops and network expansion; earth ground screw p. 1
- Power input
- 12-volt DC POWER input for Accu-Time power packs PN 17-2004-00 or 17-2004-01 p. 1
- Power draw
- Passive device p. 1
- Dimensions
- 1.18" H x 5.65" W x 5.46" D (3.00cm H x 14.35cm W x 13.87cm D) p. 1
- Weight
- 1.0 Lbs. p. 1
- Operating temperature
- 32° to 110°F (0° to 45°C) p. 1
- Humidity
- 20-90% non-condensing p. 1
- Power jumpers
- JP1-JP4: NC feeds DC POWER to that drop's modular jack, NO cuts it off p. 1
- Terminal block power
- DC POWER is carried to pin 7 of the three terminal block connectors p. 1
What this manual walks you through
- Setting jumpers JP1-JP4 to power or not power each drop p. 1
- Removing power from the terminal block connectors p. 1
Good to know
- The RS485 termination points on the modular jacks and terminal blocks are all wired in parallel. p. 1
- Accu-Time recommends always using pin 6 of the terminal blocks as the common power ground reference. p. 1
- The jumper assignments are printed on the junction box label. p. 1
Questions this manual answers
What power supply does the Accu-Time 98-9006-00 use?
Its 12-volt DC POWER input takes the Accu-Time power packs PN 17-2004-00 or 17-2004-01. p. 1
What connectors does the Accu-Time Network Junction Box have?
Four 8-pin modular jacks for direct terminal connections and three 8-pin terminal block connectors for drops and network expansion, plus an earth ground screw. p. 1
How do I stop the junction box from powering a terminal?
Set that drop's jumper (JP1-JP4) to NO; to keep power off the terminal blocks, leave out the trunk wire on pin 7. p. 1
What are the dimensions of the Accu-Time 98-9006-00?
1.18" high, 5.65" wide and 5.46" deep, and it weighs 1.0 Lbs. p. 1
The file
Size and text
Every page · 1
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 1
Open in the PDF
The text of page 1, from the PDF itself
NETW ORK JUNCTION BOX 98-9006-00 The Accu-Time PN 98-9006-00 Network Junction Box is a communication adapter and network branch point. The Network Junction Box accommodates bi-directional RS485 communication signals from Accu-Time RS485 multi-dropped Data Collection Terminals (DCT), and RS485 communication signals from trunk wiring sources. The Network Junction Box has four (4), eight (8) pin modular jacks which can accommodate direct DCT inputs, and three (3), eight (8) pin terminal block connectors which serve as Drop terminations and network expanders. The RS485 communication signal termination points are all parallel on both the modular jack and terminal block connectors. The Accu-Time Network Junction Box is equipped with a terminal screw for "Earth Ground" terminations. The 12-volt "DC POWER" input supports the Accu-Time (PN 17-2004-00 or 17-2004-01) power pack assemblies. Depending upon the configuration of the Network Junction Box, power may be supplied to the Accu-Time DCTs via the modular jacks and/or the terminal block connectors. The Accu-Time Network Junction Box is equipped with selectable jumper connectors labeled JP1-JP4. In the "NC" option, power supplied to the "DC POWER" input is applied to the modular jack of the appropriate "DROP" connector. In the "NO" option, power from the "DC POWER" input is disabled from the appropriate "DROP" connector. (NOTE: Refer to Network Junction Box label for jumper assignments). Power applied to the "DC POWER" input is carried to pin 7 of the three terminal block connectors. To disable power from the terminal block, omit network trunk wire on pin 7 during installation. Accu-Time recommends that pin 6 of the terminal block connectors always be utilized as a common power ground reference point. (NOTE: Refer to the Accu-Time Technical Support Department for recommended installation guidelines). 1 .1 8 i n
GENERAL SPECIFICATIONS1254678 P.GNDE.GNDCO M MP.GND548+VDC37P.GND26+VDCE.GNDCO M M1
EnvironmentalOperating Temp: 32°-110°F (0°-45°C) Relative Humidity: 20-90% Non-condensing
3
P.GND
PhysicalDimensions: 1.18" H X 5.65" W X 5.46" D (3.00cm H x 14.35cm W x 13.87cm D) Weight: 1.0 Lbs.
6785.65in 1354P.GNDCOMM+VDCP.GNDE.GND
Operating ParametersPower: Passive device
2D C PO W ER JP 1NCJP 2JP 3D RO P 1JP 4 NCNOD RO P 2DR OP 3D RO P 4NOE.GN D5.46in98900600.doc
Accu-Time Systems, Inc. 420 Somers Road, Ellington, CT 06029 Tel (860)870-5000 Fax (860)872-1511