Page 11

AccuLazr Interface Module The AccuLazr Interface Module is fully compatible with the AL5010 line of barcode readers and is available in both a Basic and Enhanced version. The AccuLazr Basic Interface Module provides the following connections: Scanner (15-pin and RJ45) Ethernet / EtherNet/IP (1) Serial ports (2) Trigger Input Power

The Enhanced Interface Module provides the following additional connections: Tach Input Up to four Opto22 I/O modules Fieldbus communications (either DeviceNet or Profibus)

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 12

AccuLazr™ User Interface The AccuLazr User Interface lets you configure an AL5010 through a series of intuitive, user-friendly menus, tools and dialog boxes accessed via a web browser. Context sensitive help is available to assist with use of the software.

With the user interface, you can: Integrate AL5010 to your system and application without custom software. Modify output messages to accommodate your system needs. Add or modify the barcode symbologies read by AL5010. Define up to four (4) relay input/outputs. Monitor AL5010 performance using diagnostic tools. Fine-tune optional adjustable raster. You can easily configure your AL5010 reader by using a desktop or laptop computer, an Ethernet network connection and the browser-based interface.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 13

Typical AL5010 Mid-Range Barcode Reading Applications Use the AL5010 in the following applications: single-reader applications (side or top) pick module scanning multi-sided scanning retail distribution centers industrial manufacturing With optional Adjustable Raster: pallet scanning hard-to-read barcodes plastic shrink-wrapped barcodes unknown label positioning

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 14

6

AccuLazr™ AL5010 Product Line Manuals

Introduction

Options and Accessories Contact your sales representative for assistance in determining which options and accessories will be applicable to your application. If you know which items are needed, contact Accu-Sort’s Customer Service Department (ask for the Spare Parts Coordinator) between 8 AM and 4:30PM (EST) Monday through Friday at 1-800-BAR-CODE (Fax: 215-7231515).

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 15

2 Safety Please follow the safety precautions and warnings found in this manual when installing, setting up, operating, maintaining, troubleshooting or replacing any Accu-Sort products, parts, or related equipment. Following these precautions will prevent personal injury or damage to the unit. Failure to follow these precautions may also void your warranty. This section provides important information regarding safety and your AL5010, especially involving issues regarding:

General Precautions during Mounting and Installation

Compliance Requirements

Electrical Safety

Electrical Grounding Requirements

Electrostatic Discharge Precautions and Control

Laser Safety

Contact Accu-Sort at 1-800-BAR-CODE™ if you need more information.

Symbols Throughout this manual, special safety alerts are indicated by the following symbols: WARNINGS or CAUTIONS: This symbol identifies a hazard or procedure that, if incorrectly performed, could cause personal injury or result in equipment damage. HIGH VOLTAGE CAUTION: This symbol alerts the user they are about to perform an action involving, either a dangerous level of voltage, or to warn against an action that could result in damage to devices or electrical shock. LASER CAUTION: This symbol alerts the user they are about to perform an action involving possible exposure to laser light radiation. ESD CAUTION: This symbol identifies a procedure that requires you take measures to prevent Electrostatic Discharge (ESD) e.g., use an ESD wrist strap. Circuit boards are most at risk. Please follow ESD procedures. Alerts help you to:

Identify a hazard and its consequences

Avoid a hazard by taking adequate safety precautions

Get the most out of your bar code solution

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 16

General Precautions Installation and Service by Qualified Service Technician Only WARNING: All procedures involving exposure to the inside of the AL5010 Interface Module must be performed by a trained technician because of possible exposure to emitted laser radiation, high voltage, and could reduce the effectiveness of the device’s IP rating. There are no user-serviceable parts inside. Do not attempt to open the unit or perform any installation/service procedures unless you are a trained technician! DO NOT REMOVE the faceplate from the scan head enclosure. Opening the AL5010 will void the factory warranty. Refer all servicing and advanced troubleshooting to a qualified service technician. Technical training is available from Accu-Sort Systems. Furthermore, even trained technicians should always reference the specific product documentation for more detailed service procedures that may not be described in the AL5010 Product Manual.

Unpacking, Mounting and Installation Recommendations CAUTION: Firmly fasten mounting structures in place before installing the equipment to any mounting structure. Avoid using freestanding mounting structures. If your application requires a freestanding mounting structure, avoid making the structure top-heavy.

Follow all procedures regarding electrical safety, laser safety, and electrostatic discharge safety (ESD) as outlined in this manual.

Save all packing material in case you have to transport your readers.

Use steel or aluminum as a mounting structure. An Accu-Sort mounting structure is recommended for optimum system performance.

Check mounting hardware periodically for tightness and stability.

Do not use sheet rock, plaster board, wood, or other unstable mounting surfaces.

Do not use mounting surfaces that are subject to high vibrations.

Do not create any obstructions of airflow around the modules. Keep the area around the modules clean to provide for cooling. (Refer to specific product manuals for minimum clearances.)

Avoid dropping the readers during unpacking and installation.

Do not touch the window glass of the scan head.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 17

Compliance Requirements FCC NOTICE: The AL5010 has been tested and found to comply with the limits for a Class A digital device, pursuant to Title 47, Part 15 of the FCC Rules. These limits are designed to provide a reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manuals, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. WARNING: These are Class A products. In a domestic environment, these products can cause radio interference, in which case the user may be required to take adequate measures. (Ref. CISPR 22 = EN 55 022:1995.) IMPORTANT: Follow the guidelines below to maintain Electromagnetic Compatibility (EMC) Compliance:

Interconnecting cables must be twisted pair cables.

All shielded I/O cables shall have the shield terminated to the chassis.

NOTE: DRAIN WIRE SHIELDING IS NOT ADEQUATE.

Do not remove the shielding covers.

Refer to the details on making custom cables as provided in the specific technical manual for the component.

Electrical Safety AL5010 must be installed in accordance with Canadian Electrical Code, Part I, CSA C22.1; CSA C22.2 No. 0; and the National Electrical Code, NFPA 70. For complete requirements, National Electrical Code, ANSI/NFPA 70, Canadian Electrical Code, Part I, C22.1, or other national standard must be consulted.

For PERMANENTLY CONNECTED EQUIPMENT/RACK MOUNTED, incorporate a readily accessible disconnect device in the fixed wiring.

For PLUGGABLE EQUIPMENT/RACK MOUNTED, install the socketoutlet near the equipment so it is easily accessible.

Make sure that all personnel who work with the equipment know where the disconnect switches or circuit breakers are located.

Before performing any type of maintenance, turn off power to the unit and disconnect the power cord.

Be certain your hands and the floor of your work area are dry before touching electrical equipment or connecting cords.

Routinely check all power cords, plugs, wiring, and cable connections for any signs of exposed wire or deteriorating insulation. If you notice any damage, make arrangements with service personnel to repair or replace the damaged item immediately.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 18

Electrical Grounding Requirements Before applying power to any device, ALL components MUST be electrically grounded. Follow these precautions:

Ensure all AC power outlets have a properly grounded receptacle.

ALL components MUST be properly cabled and grounded with threeconductor AC power cords.

Use the correct power cord for your country.

Reference specific grounding instructions for each component.

Do not use a two-prong adapter.

Do not cut/remove the round grounding prong from any plug.

Do not use an extension cord to defeat any ground.

Electrostatic Discharge ESD CAUTION: Measures must be taken to prevent Electrostatic Discharge (ESD) at all times when handling any product, equipment, unit or part (e.g. use a grounded ESD wrist strap). It should be noted that circuit boards are at greatest risk to damage from ESD. Please follow standard ESD precautions! Electrostatic discharge (ESD), the transfer of static electricity from one object to another, is an often-unnoticeable hazard to electronic components. Boards and other devices with integrated circuits are particularly sensitive to ESD damage. Product failures may not occur until days or weeks after the component was damaged. Static damage to units can take the form of upset failures or catastrophic failures (direct and latent). An upset failure occurs when an electrostatic discharge is not significant enough to cause total failure, but may result in intermittent gate leakage, causing loss of software or incorrect storage of information. Direct catastrophic failures occur when a unit is damaged to the point where it is permanently damaged.

Basic Rules for ESD Control Below are some keys to effectively control unnecessary ESD damage when working with ESD-sensitive devices:

Define an ESD protective area and work on the ESD-sensitive devices in this area only.

Define static sensitivity of devices to be handled in ESD protective area.

Establish suitable static control program that limits static generation to less than the damage threshold of the most sensitive device and provides a safe, defined path for static charge dissipation.

Prevent contamination of the protective area by unnecessary non-static controlled materials.

Audit the ESD protective area regularly to ensure that static control is maintained. Document the findings for future reference.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 19

Refer to the specific ESD precautions for each component.

Laser Safety The AL5010 uses visible laser diodes and emits a “moving” red beam. Do not stare into the AL5010’s exit window at the laser light source. Avoid unintentional exposure to laser light whenever possible. The laser light level does not constitute a health hazard, however staring at the laser light for prolonged periods could result in eye damage. The following appears next to the AL5010 laser exit window: WARNING! LASER LIGHT EMITTED FROM THIS APERTURE

Warning on AL5010 Laser Exit Window to Avoid Exposure

WARNING: Use of controls, adjustments, or procedures other than those specified in this document may result in hazardous laser light exposure. The AL5010 Line Scanning Bar Code Reader is rated as a Class 1 Laser Product by the International Electrotechnical Commission. Compliances are as follows: Class 1 Laser Product (IEC-60825-1) 2007. Before performing any maintenance or service procedures, perform the laser shutoff procedure provided in Chapter 7.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 20

12

AccuLazr™ AL5010 Product Line Manuals

Safety

Safety Labels and Locations Refer to the following figures for specific label locations and warnings. When operating, repairing, or replacing an AL5010, note all label content on the unit. These labels provide special precautions for operation, usage specifications, product identification, and service information. WARNING: LASER LIGHT EMITTED FROM THIS APERTURE.

Label Placement AL5010 Scan Head