Page 181
I/O 1 Configuration = Used as output
Selection Custom Output
Definition Used for applications involving custom software to select a customized output option.
Life Light
Always on while the reader is operating.
Trigger Output
Echoes the status of the trigger signal.
Error Light
Active in the event of an error condition (see later section on errors currently detected). Active if all expected codes are read.
Good Read Output No-Read Output
Active if not all expected codes are read.
Match Output
Active if any code matches the match code criteria.
No Match Output
Active if no codes match the match code criteria (includes noreads).
Good Read and No Match Output
Active if a code was read but did not match the match code criteria.
Multiple Output
Active if too many codes were read.
Multiple or NoRead Output
Active if too many codes were read or a no-read occurred.
Active Low/ Active High
Select Active Low or Active High from the drop-down list.
Output Signal Duration (ms)
• Active Low: The trigger is active when the input signal is low. • Active High: The trigger is active when the input signal is high. Enter a duration in milliseconds for the output signal.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 182
Modify Settings > Tracking
Tachometer (Encoder) Selections (drop-down list) Selection Hardware/ External (Only available with T Enhanced the Interface Module) a
Definition Used for external hardware tachometer. When this tachometer mode is used, you must also set the number of pulses per inch (PPI) generated by the tachometer.
Constant/Internal
Specify the tach rate to be used (from 25 - 600 ft/min). No external hardware is used.
c h o Computed Tach m e t
There are two options available: Start-End and Start-Start. In both cases, you specify the Length (from 1-200 inches) between either a start and end trigger (Start-End) or between one start trigger and the next (Start-Start). From this information the reader will compute the belt speed and generate an internal tach signal.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 183
Selection Reader Mounting
Definition Closest Read Point – Specify the nearest distance from the reader where the reader is expected to read a bar code. Farthest Read Point – Specify the furthest distance from the reader where the reader is expected to read a bar code. Trigger Reference Point – Specify the distance from the trigger signal to the center point of the scan line. Reader Rotation – Specify any rotation of the scan line with respect to the motion of the belt. Set a rotation direction from –180 to 180 degrees.
Transmit
Transmit Edge – Specifies which edge of the package (leading or trailing) is used to reference the transmit point. Transmit Point – The point at which bar code data is transmitted. Defines the number of inches after the specified edge of the package passes the trigger before data transmission occurs.
Tracking Configuration
Extend Front (in.) – Use to increase the virtual size of the package by increasing the leading edge (front) of the package. Extend Back (in.) – Use to increase the virtual size of the package by increasing the trailing edge (back) of the package. Tolerance – Specify the tolerance (in inches) for associating a label with a box.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 184
Modify Settings > FAST Monitor™
NOTE: For more information on FAST Monitor functionality, see the FAST Monitor Product CD, online help or contact us at 1-800-BAR-CODE. Selection Tunnel Information
Definition Tunnel Name – Assign a name for the tunnel/array.
FAST Monitor Port
Port No. – If the reader is a standalone unit or controller in a scanning tunnel, set the FAST Monitor Port information. The port number is always 9899.
Reader Position – Select the Reader Position from the dropdown menu. Reference the illustration for relative positions.
Reconnect Time – Enter a reconnect time for this port. Remote IP Addr. – Enter the IP Address for the FAST Monitor Server.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 185
Modify Settings > Advanced
CAUTION: Changing the Advanced settings can adversely affect reader performance. These settings are to be modified only under the guidance of Accu-Sort Technical Support. Selection Data Filtering
Definition Scan Filtering (Skip Scan) – Laser n DOF: Near/Far Dist (in) – Enter near and far distance depth of field for the laser. Minimum Transitions – Enter the minimum transitions allowed.
Bar Code Size
Scan Rate – Displays the scan rate. Field of View – Displays the filed of view. Min Narrow Element (mils) – Enter the minimum width of the barcode’s narrowest element in thousandths of an inch. Max Narrow Element (mils) – Enter the maximum width of the barcode’s narrowest element in thousandths of an inch. Maximum Tilt – Enter the maximum bar code tilt.
DRX Setting
DRX Enabled – Select to enable DRX NOTE: The DRX settings typically will not need to be modified. Contact Accu-Sort Support for details (1-800-BAR-CODE).
Transmit QQ
Minimum QQ – Enter the smallest allowable QQ value for a code to be transmitted. Maximum QQ – Enter the maximum QQ value. This forces the transmission of a code after the maximum QQ value is reached.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 186
Modify Settings > Raster
NOTE: The Modify Settings > Raster selection is only available on the menu tree when an AL5010 unit with the raster option.
Selection Upper Sweep
Definition Specify the upper limit of the laser from -20-degrees to +20 degrees from 0-degrees.
Lower Sweep
Specify the lower limit of the laser from -20-degrees to +20 degrees from 0-degrees. NOTE: The laser will sweep between the specified upper and lower values. Example 1: If the upper value is set at -5degrees and the lower value is set at -10degrees, the laser will sweep the 5-degree range specified below 0-degrees. Example 2: If both the upper and lower values are set at the same value, the laser will stay on that fixed value without sweeping.
Oscillating Frequency (Hz)
Specify the frequency at which the vibrating vane (mirror) will oscillate between 0 and 10 Hz. This is the speed of the mirror oscillation with 0 being effectively stopped and 10 oscillating the fastest.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 187
Save / Retrieve
Selection Save / Retrieve: Action = Save
Definition To – Select File, Reader, or Base from the drop-down list.
Selection Save / Retrieve: Action = Retrieve
Definition From – Select File or Base from the drop-down list.
Selection Save / Retrieve: Action = Default
Definition Use to return the reader’s parameters to the hard-coded "default" values built into the reader software.
• File: Use to specify a file name and location to store the current parameter settings on your computer. • Reader: Use to save the current set of parameters to the reader. Parameters saved in the reader are the parameters used during normal operations. • Base: Use to save the current set of parameters to the mounting base as a backup copy.
• File: Use to retrieve a parameters set from a specific file name and location on your computer. • Base: Use to retrieve the parameters stored in the reader’s mounting base. This is especially useful when it becomes necessary to load the correct parameters to a replacement reader module.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 188
Selection Reboot AL5010
Definition Click to reboot the bar code scanner.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 189
Diagnostics
Diagnostics The Diagnostics main page describes the items available in its menu tree.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 190
Diagnostics > Monitor
NOTE: The Monitor is a Java application and requires Java and the appropriate browser plugin.
Selection Status LEDs
Definition Status – GREEN to indicate the overall "health" of the reader. (If RED, troubleshooting is required.) Trigger – GREEN indicates the trigger input. The LED is activated upon trigger input regardless of trigger source (including software trigger). Good/No Read – GREEN indicates a good (valid) bar code has been decoded. RED indicates a no-read (or incomplete decode). Multiple codes – RED indicates more codes than desired were read. Match – GREEN indicates a code matches the Match Code criteria. Network – GREEN indicates a network host connection has been made. RED indicates a problem with the reader network. • Example: A red Network LED upon power up could indicate the MAC address was not set at the factory. Network (multi-reader networks only) – GREEN indicates a valid connection to a Controller or Client. Flashing RED on a
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net