8 Troubleshooting This chapter provides instructions for diagnosing, troubleshooting and correcting AccuLazr AL5010 performance issues. It provides specific information on:
Test Mode
Indicators
Diagnostics
Troubleshooting (Problem/Cause/Solution)
Test Mode In test mode, the AL5010 displays the read rate on the AL5010 control panel’s bar graph LEDs. The Diagnostics > Monitor window also provides a read quality bar graph that enables you to monitor the test mode remotely from a PC connected to your network. Additional details can be obtained by monitoring from this diagnostic window while the reader is in test mode. NOTE: Test mode will continue running until you click Stop Test Mode on the Monitor screen or press the button on the back of the reader.
Status Indicators The AccuLazr AL5010 provides several status indicators that you can use to troubleshooting performance during operations. They are found at two locations:
Control Panel
Diagnostics > Monitor screen
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 122
Control Panel Indicators There are several control panel indications on the AccuLazr AL5010 Readers and AL5010 Interface Module.
AL5010 Reader Control Panel
Basic Interface Module Enhanced Interface Module AL5010 Interface Module Status Indicator LEDs
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 123
Control Panel LED Fault Detect Descriptions LED
Description
STATUS
RED indicates a problem regarding the overall "health" of the reader.
TRIGGER
Indicates the trigger input. The LED is controlled through software no matter the trigger source (including software trigger).
READ
RED identifies a No Read condition. Check bar code print quality, trigger configuration, and bar code parameters.
RX/TX
If bar codes are being read, but the LED is NOT illuminated, data is not being transmitted on serial port 1.
NETWORK
(See Network LED – Fault Detection.)
LINK
If the LED is not flashing, there is no network connection.
Bar Graph
Read quality indicator (5 = Good, 1 = Poor).
(LED 1 – 5)
5 = 81-100% 4 = 61-80% 3 = 41-60% 2 = 21-40% 1 = 00-20% NOTES: Also flashes during parameter upload/backup.
(Laser Shutoff)
LEDs stay on when Test/Diagnostic button C is pressed during the laser shutoff procedure.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 124
NETWORK LED – Fault Detection Only Mode Single TCP/IP
Description LED is Off – No host connection or UDP messaging is used. NOTE: If UDP messaging is used (unconnected messages) the Network LED will be off. EtherNet/IP Flashing GREEN – No connection made with the network Flashing RED – Lost network connection Controller/Client Controller Flashing RED – All the client(s) with the same group number have NOT been found or a client’s tracking does not match the controller. Client Off – Not connected to a controller with the same group number. Match the client to the controller’s group number. Solid RED – Client’s tracking does not match the controller. NOTE: The mode indicated by the Network LED is dependent on the AL5010 configuration you are using. Ethernet/IP is the highest priority, Single TCP/IP mode operation is the lowest. NOTE: See Network LED during Normal Operations.
Control Panel Buttons – Uses during Troubleshooting Ref.
Button
Description
Restore to Scan Head
Use to restore a set of parameters from the wiring base to a replacement scan head. NOTE: This only works if the Backup to Base button has been used earlier to assure the correct parameters are stored in the wiring base.
Backup to Base
When it becomes necessary to replace a scan head, be sure to use this button to download a backup set of parameters from the scan head to the wiring base. By doing this, it is easy to configure your replacement scan head by using the Upload to AL5010 button.
Test /Diagnostic
Enables the AL5010 test mode.
(Laser Shutoff)
(Test mode can also be selected remotely using Tools > Commands > Test Mode On.) Use to perform laser shutoff.
NOTE: Keep in mind that the buttons on the reader’s control panel can be enabled/disabled through the use of the AccuLazr user interface. (For details, see Chapter 5.)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 125
Diagnostics The AccuLazr User Interface includes comprehensive diagnostic capabilities that monitor reader operation, triggering, conveyor speed, package and label dimensions, bar code readability, scan rates and message output. The Diagnostics > Monitor window is the primary tool used to monitor the reader's operation and bar code readability in real-time. The Diagnostics > Log Viewer lets you review the performance logs saved by the AL5010. The log view field remains empty until you select one of the three buttons (Read Rate, System Counters, or Message Log). Update Firmware is used to reload the reader firmware.
Monitor Status indicators and vital statistics appear on a single screen, enabling you to effectively and efficiently detect and troubleshoot any problems that may occur in high-speed laser bar code scanning.
Diagnostics > Monitor (Active)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 126
Status LEDs
The Monitor status indicators reflect the AL5010 control panel LEDs functionality as well as additional LEDs such as the Match and I/O LEDs. Status LED Definitions LED Conditions Status Green Red Trigger Green
Definition of Conditions
Indicates the overall “health” of the reader. Fault condition: Troubleshooting is required. Indicates the trigger input. The LED is activated upon trigger input regardless of trigger source (including software trigger).
Good/No read Green Indicates a good (valid) bar code has been decoded. Red Indicates a no-read (or incomplete decode). Multiple codes Red Indicates more codes than desired were read. Match Green Indicates a code matches the Match Code criteria. Network Flashes green or red to indicate connection status. Example: A red Network LED upon power up could indicate the MAC address was not set at the factory).
For a Single TCP/IP connection, it indicates that a "host" connection has been made to the reader.
For EtherNet/IP connection, it indicates "network" connection status. This LED is software controlled.
For Controller/Client multi-reader connections, it indicates all inter-reader communications (i.e., connections between readers) are correctly functioning. I/O #1 through I/O #4 Green Indicates the status of the programmable I/O lines.
Network LED during Normal Operations Mode Single TCP/IP
Description Solid green – AL5010 connected to a host. NOTE: If both Host 1 and Host 2 are used, the LED will be solid green if either port is connected. Off – No host connection. NOTE: If UDP messaging is used (unconnected messages) the Network LED will be off. EtherNet/IP Solid green – AL5010 made a connection to the PLC Flashing green – No connection made with the network Flashing red – Lost network connection Controller/Client Controller Solid green – The correct number of client(s) with the same group number have been found. Flashes red – All client(s) with the same group number have NOT been found Client Solid green – Connected to controller with same group number. Off – Not connected to controller with same group number. NOTE: The mode indicated by the Network LED is dependent on the AL5010 configuration you are using. Ethernet/IP is the highest priority, Single TCP/IP mode operation is the lowest.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 127
Read Quality
The Read Quality indicators provide information regarding the bar code that was read. Read Quality Definitions Read Quality Graph 0-100 Scans/Code Code Position (slider) Code Quality (QQ) Laser 1 through 4
Definition The large percentage bar maps to the values displayed on the reader bargraph. It is a measure of “how well” the bar code was read. Indicates how many passes of the laser (scan lines) contributed to the reading of the code. Indicates the bar code’s position in the AL5010’s scan line (from zero to 4095). Indicates the QQ (code quality) value for each laser that read the bar code.
Box Information The availability of diagnostic information within these fields depends on whether tracking is enabled or not. The first three are only available in tracking and the last one only in triggered, non-tracking modes. These items are only updated when a trigger occurs. To monitor belt speed more accurately, it can also be viewed as part of the System Counters in the log viewer. Box Information Definitions Box Information Belt Speed (FPM) Box Length (inch) Code Position (inch) Scans/Trigger
Definition Belt/conveyance speed in feet per minute Box/package length in inches Bar code position on the box in inches Number of scans per trigger cycle
Messages Diagnostic messages from the reader are displayed here. This is primarily information on each bar code read. Message Monitor The message monitor can be used to monitor the messages being sent from any of the reader host ports (either serial or network). As with messages, options for clearing, starting, stopping and logging this information are made available by right clicking. Message Monitor Definitions Message Monitor (Display Field) None Com Port #1 Com Port #2 Net Host #1 Net Host #2
Definition Displays the message transmitted Select the port to be monitored. The AL5010 will not attempt to send messages out Net Host ports unless a connection is already established. Note: Nothing is displayed on Net Host #1 if EtherNet/IP communications are being used.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 128
Log Viewer The Diagnostics > Log Viewer lets you review the performance logs saved by the AL5010. The log view field remains empty until you select one of the three most common logs (Read Rate, System Counters, or Message Log) via the buttons or enter a log request in the Command field. Log Viewer Commands There are several commands that you can use to display AL5010 parameters and diagnostic information. Commands can be sent from the Command field on the log viewer. Commands may also be sent from a terminal interface, such as a TELNET connection to the AL5010. Log Viewer Command Descriptions Display Commands DISP COUNTERS DISP ENET DISP LASERS DISP LASERx DISP MSGLOG DISP READRATE Other Commands CLEAR ALL
Description
Display the System Counter log view. Display the Ethernet interface status including MAC address. Display ALL Lasers log view. Display one Laser log view, where X is 1 – 2. Display the Message log view. Display the Read Rate log view. Description Clears all information from the Message Monitor.
NOTE: All commands can be issued from the Command field. However, when entering a command in the field, spaces are NOT permitted. As a result, the display commands need to be entered without a space (i.e., DISPCOUNTERS, DISPMSGLOG, etc.) NOTE: Right-click on log view provides two options: Save LogView to File (also available from Tools) and Copy to Clipboard.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 129
Read Rate Log View For a summary of the AL5010’s overall performance, click the Read Rate button. You can also enter DISPREADRATE in the command field and click Send.
Diagnostics > Log Viewer (Read Rate selected) The Read Rate Log Viewer provides information on the overall read rate. Overall Read Rate Counters Read Rate Total Boxes Good Boxes
Partial Boxes Bad Boxes
Description Total number of triggers. A good box is a box with all required codes. This counter is the number of good boxes along with the percentage of the total boxes that were good. A partial box is a box were some, but not all required codes were read. This obviously only applies when the AL5010 is configured to read multiple codes each trigger. A bad box is a box where no codes were read.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 130
The Read Rate Log Viewer also provides performance information on each laser. In order to provide diagnostics on the performance of each laser, the percentages reference here are the percentage of the total codes read by the particular laser, NOT the percentage of the total packages read by that laser. Read Rate Counters per Laser Read Rate Total Codes Laser#x
Description Total number of bar codes read. Total number of bar codes read by the particular laser.
For an AL5010 configured as a Controller in a multi-reader network, this command also provides counters for the number of bar codes read, by laser, for each AL5010 client. The clients are identified by their reader name as assigned in Modify > Configuration. (See Chapter 5.) REMEMBER: Not every AL5010 is configured with two lasers.