7. Run the browser-based setup application and establish a connection with the reader. 8. Go to the Diagnostics > AL5010 Monitor. 9. During operations, use the AL5010 Monitor to confirm the reader’s status, read quality, code quality, and messages via the on-screen indicators. (See Chapter 8, Diagnostics.) 10. Close the connection to the reader. 11. Disconnect setup cable.

Operations Checklist

Check trigger photoeye LED for proper operation.

Test parameters to assure optimal operation.

Observe the reader’s Status Indicator LEDs during power-up. (What to watch for is outlined on page 95.)

Select Diagnostics > AL5010 Monitor.

Pass test label in scanning beam.

Adjust mounting as needed for optimal performance.

Modify AL5010 parameters as needed for optimal performance.

Save parameters to scan head.

Backup parameters from scan head to mounting base.

Backup parameters to disk (optional, but recommended).

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 102

Control Panel Indicators There are several control panel indications on the AccuLazr AL5010 Readers and AccuLazr Interface Modules.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 103

The LEDs provide the following indications during normal operations. Using LED Indicators to Check Normal Operations LED

Description

STATUS

GREEN to indicate the overall "health" of the reader. (If RED, see Chapter 8, Troubleshooting.)

TRIGGER

Indicates the trigger input. The LED is activated upon trigger input regardless of trigger source (incl. software trigger).

READ

Flashes red or green based upon the software criteria.

RX/TX

LED for serial port 1.

NETWORK

Flashes red or green to indicate connection status.

GREEN = Transmitting data RED = Receiving data

For a Single TCP/IP connection, it indicates that a "host" connection has been made to the reader.

For EtherNet/IP connection, it indicates "network" connection status. This LED is software controlled.

For a Controller/Client multi-reader connection, it indicates that all inter-reader communications (connections between readers) are correctly functioning.

LINK

This LED is LINK indicator for Ethernet. Flashes GREEN when connected to a network.

Bar Graph (LED 1 - 5)

Scan quality indicator.

Flashes when parameters copied to/from mounting base.

LEDs stay on when Test/Diagnostic button C is pressed during the laser shutoff procedure.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 104

NETWORK LED during Normal Operations Mode Single TCP/IP

Description Solid GREEN – AL5010 connected to a host. NOTE: If both Host 1 and Host 2 are used, the LED will be solid GREEN if either port is connected. Off – No host connection. NOTE: If UDP messaging is used (unconnected messages) the Network LED will be off. EtherNet/IP Solid GREEN – AL5010 made a connection to the PLC Flashing GREEN – No connection made with the network Flashing RED – Lost network connection Controller/Client Controller Solid GREEN – The correct number of client(s) with the same group number have been found. Flashing RED – All the client(s) with the same group number have NOT been found Client Solid GREEN – Connected to a controller with the same group number. Off – Not connected to a controller with the same group number. NOTE: The mode indicated by the Network LED is dependent on the AL5010 configuration you are using. Ethernet/IP is the highest priority, Single TCP/IP mode operation is the lowest.

Using Control Panel Buttons to Check Normal Operations Ref

Button

Description

Restore to Scan Head

Restores parameters from Mounting base to Scan Head Button must be pressed twice to initiate action. See page 99 for procedure.

Backup to Mounting Base

Downloads parameters from Scan Head to Mounting base Button must be pressed twice to initiate action. See page 99 for procedure.

Test /Diagnostic (Laser Shutoff)

Enables the AL5010 test mode. (Test mode can also be selected remotely using Tools > Commands > Test Mode.) Use to perform laser shutoff. (See page 107.)

REMEMBER: AL5010’s control panel buttons can be enabled / disabled through the use of the browser-based setup application. (See Modify > AL5010 Configuration, Enable AL5010 Control Panel Buttons.)

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 105

Interface Module Status Indicators

LEDs on Basic Interface Module

LEDs on Enhanced Interface Modules

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 106

FieldBus LED Status Indicators DEVICENET Module Status FB1 FB1 FB2 FB2 Network Status FB3 FB3 FB4 FB4

Off - No power Green Normal operation Green, flashing Auto Baud in progress Red Unrecoverable Fault(s) detected Red, flashing Recoverable Fault(s) detected Alternating Red/Green Self test in progress Off - Not online - or - no power Green On-line, one or more connections established Green, flashing On-line, no connections established Red Critical link failure Red, flashing Connection timeout Alternating Red/Green Self test in progress

PROFIBUS LED State FB1 Clear (0) Set (1) Toggling (1Hz) FB2 ASIC

Color Off Green Green, flashing

Description Node Off-Line or Power not supplied Node in Data Exchange Mode Node in Clear Mode

Clear (0) Set (1)

Off Red

No Error or Power not supplied Error in initialization of PROFIBUS

Toggling (1Hz)

Red, flashing

Error in configuration data and/or User Parameterization Data

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 107

Backup / Restore Procedures To backup parameters from scan head to mounting base: 1. Press the backup button for about 1 second. 2. Release button. The bar graph LEDs continuously flash to indicate the button has been pressed long enough. If the LEDs flash only once, the button was not pressed long enough. 3. Press button a second time while LEDs are flashing. Hold for about 1 second. 4. Release button. The bar graph LEDs strobe from 5 to 1 indicating parameters are being backed up from scan head to mounting base. 5. When the LEDs stop strobing, the backup is complete. To restore parameters from mounting base to scan head: NOTE: The restore parameters function can cause the scanner to reboot. 1. Press the restore button for about 1 second. 2. Release button. The bar graph LEDs continuously flash to indicate the button has been pressed long enough. If the LEDs flash only once, the button was not pressed long enough. 3. Press button a second time while LEDs are flashing. Hold for about 1 second. 4. Release button. The bar graph LEDs strobe from 1 to 5 indicating parameters are being uploaded from mounting base to scan head. 5. When the LEDs stop strobing, the upload is complete.

Restore

Backup

Button and LEDs involved with Backup / Restore

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 108

Checking Operations with User Interface The Diagnostics > Monitor enables you to evaluate the operational performance of your AL5010 by providing vital statistics via status indicators, real-time read quality monitoring, and box information. Outgoing and incoming messages are also monitored.

Diagnostics > Monitor Window

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 109

Checking Multi-Reader Network From the AL5010 Controller, check Diagnostics > Log Viewer > Read Rate. This simple diagnostic allows you to check bar codes read, by laser, for each AL5010 Client in the network. Each client is identified in the Read Rate Log by the unique name and IP address assigned to it. See Chapter 5 and online help for more information.