A four-page Allen-Bradley instruction sheet (40062–308–01(A), 1995) for the AdaptaScan Wiring Bases, catalog numbers 2755-NB40 (US version) and 2755-NB41 (metric version). The wiring base holds all the wiring connections of the AdaptaScan Reader and two I/O module sockets. The sheet gives mounting guidelines, dimensions and clearances, top and bottom mounting, hole plugs and the dust cover, but no wiring diagram.
- Device
- Wiring base with all wiring connections for the AdaptaScan Reader and sockets for two I/O modules p. 1
- Versions
- 2755-NB40 U.S. version, 2755-NB41 metric; they differ only in conduit openings and bottom mount thread sizes p. 1
- Conduit openings
- Four conduit openings; 3 conduit plugs supplied p. 1, 4
- Hole plugs
- 2755-NB40: N.P.S.C. threaded plug, sealed with teflon tape, tightened with a 3/8 in. hex wrench; 2755-NB41: plug with O-ring p. 4
- Bottom mount threads
- 2755-NB40: #10-32 UNF-2B; 2755-NB41: M5 x .8; three holes .6 inch (15 mm) deep p. 3
- Top mounting screws
- Three #10 or M5 screws, heads under 3/8 inch diameter, 1/2 inch (12.5 mm) long plus the depth into the surface p. 3
- Enclosure
- NEMA Type 4 when unused conduit openings carry the hole plugs p. 4
- Mounting bracket kit
- 2755-NM42, used with the three screws supplied with the wiring base p. 1
- Mounting template
- Full size template No. 40062–310–01 supplied p. 3
- Clearance
- 1 inch (25.4 mm) for Reader installation and viewing the LED indicators p. 2
What this sheet walks you through
- Planning the mounting position, wiring routes and grounding p. 1
- Dimensions and clearances of the wiring base and Reader assembly p. 2
- Mounting the wiring base from the top p. 3
- Mounting the wiring base from the bottom into its threaded holes p. 3
- Sealing unused conduit openings with hole plugs p. 4
- Fitting the dust cover when no Reader is installed p. 4
Good to know
- All cables must be shielded and grounded at one end to avoid EMI problems. p. 1
- Where communication and power wiring cross, make the crossing perpendicular. p. 1
- Bottom mounting screws must not be longer than 1/2 inch (12.5 mm) plus the thickness of the mounting surface. p. 3
- The dust cover is only temporary protection until a Reader is installed. p. 4
Questions this sheet answers
What is the difference between the 2755-NB40 and 2755-NB41?
The 2755-NB40 is the U.S. version and the 2755-NB41 the metric one; only the conduit openings and bottom mount thread sizes differ. p. 1
What screws mount the AdaptaScan 2755-NB40 wiring base?
From the top, three #10 or M5 screws; from the bottom, screws into its #10-32 UNF-2B threaded holes. p. 3
What does the AdaptaScan wiring base do?
It holds all the wiring connections for the AdaptaScan Reader and has sockets for two I/O modules. p. 1
How do I seal unused conduit openings on the 2755-NB40?
Fit the supplied N.P.S.C. threaded hole plug with teflon tape or other thread sealant and tighten it with a 3/8 in. hex wrench. p. 4
The file
Size and text
Every page · 4
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 4
Open in the PDF
The text of page 1, from the PDF itself
Instructions AdaptaScan Wiring Bases Catalog Number 2755-NB40, -NB41
Wiring Bases Catalog No. 2755-NB40, -NB41
Description
The wiring base contains all of the wiring connections for the AdaptaScan Reader along with sockets for two I/O modules. Two versions of the AdapataScan wiring base are available, a metric (Catalog No. 2755-NB41) and U.S. version (Catalog No. 2755-NB40). Both versions of the wiring base are identical except for the conduit openings and bottom mount thread sizes. Note: The three screws provided with the Catalog No. 2755-NB40 or -NB41 wiring base are used with the mounting bracket kit (Catalog No. 2755-NM42).
General Mounting Guidelines
Before mounting the wiring base, determine the proper orientation and position as described in the AdaptaScan Reader user manual.
- Leave adequate clearances for wiring.
- Cover unused openings with conduit plugs (3 plugs provided with wiring base). The wiring base has four conduit openings. Use Conduit fittings with rubber grommets on cables that enter the wiring base. Two different sized grommets (for conduit fittings) are provided with each Reader.
- Route wires carefully to reduce or minimize electrical noise. When communication and power wiring must cross, make their intersection perpendicular.
- Use proper grounding to limit the effects of noise due to Electromagnetic Interference (EMI). To avoid problems caused by EMI, all cables must be shielded and grounded at one end. Grounding is also an important safety measure in electrical installations.
Connect to Earth Ground
Wiring Base
Page2of 4
Open in the PDF
The text of page 2, from the PDF itself
Instructions AdaptaScan Wiring Bases Catalog Number 2755-NB40, -NB41
Mounting Dimensions and Clearances
The following shows the dimensions clearances for the wiring base and the Reader/wiring base assembly. 3.87 Inches (98 mm)
5.36 Inches (137 mm)1.67 Inches (42 mm)1.67 Inches (42 mm)Wirng Base Front ViewWiring Base End View5.36 Inches (137 mm)3.87 Inches (98 mm)
Wiring Base Bottom View Leave 1 inch (25.4 mm) Clearance for Reader installation and viewing of LED indicators.
Midpoint of Scan Line 5.82 Inches (143 mm)
Variable
Front View
Mounting the Wiring Base
Side View
There are 2 options for mounting the wiring base (Catalog No. 2755-NB40 or -NB41):
- Top Mounting Mount the base using mounting screws through the top mounting holes.
- Bottom Mounting Mount the base using screws through the mounting surface into threaded holes on the bottom of the wiring base. 2
Page3of 4
Open in the PDF
The text of page 3, from the PDF itself
Worksheet AdaptaScan Wiring Bases Catalog No. 2755-NB40, -NB41
Top Mounting The wiring base mounts from the top to any flat surface with three #10 or M5 mounting screws. The screw heads must be less than 3/8 inch in diameter allowing them to fit inside the mounting hole. The length of the mounting screws must be 1/2 inch (12.5 mm) plus the depth the screw penetrates the mounting surface. A full size mounting template (No. 40062–310–01) is provided with the wiring base. Use the following diagram for reference. Top Mounting Holes 4.46 Inches (113 mm)
3 Holes Scan Beam2.79 Inches (71 mm)2.65 Inches (67 mm)Á Á Bottom Mounting
ÎÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎÎ
The wiring base mounts from the bottom to any flat surface with three mounting screws. The holes on the U.S. version have #10-32 UNF-2B threads. The holes on the metric version have M5 x .8 threads. The length of the screws must not be greater than 1/2 inch (12.5 mm) plus the thickness of the mounting surface. A full size mounting template (No. 40062–310–01) is provided with the wiring base. Use the following diagram for reference. Wiring Base Has Three Threaded Mountng Holes
4.46 Inches (113 mm)
Scan Beam 2.79 Inches (71 mm)
ÁÁ ÁÁ 2.65 Inches (67 mm)
ÁÁ ÁÁ
3 Holes .6 inch (15 mm) deep
Thread Size of Holes U.S. Metric
#10-32 UNF-2B M5 x .8
ÎÎÎÎÎÎ ÎÎÎÎÎÎ ÎÎÎÎÎÎ ÎÎÎÎÎÎ ÎÎÎÎÎÎ ÎÎÎÎÎÎ ÎÎÎÎÎÎ ÎÎÎÎÎÎ ÎÎÎÎÎÎ ÎÎÎÎÎÎ ÎÎÎÎÎÎ ÎÎÎÎÎÎ
3
Page4of 4
Open in the PDF
The text of page 4, from the PDF itself
Instructions AdaptaScan Wiring Bases Catalog Number 2755-NB40, -NB41
Hole Plugs Three hole plugs are supplied with the wiring base. Use these plugs on unused conduit openings to maintain the NEMA Type 4 rating.
- U.S. Wiring Base (Catalog No. 2755-NB40) The conduit opening for the U.S. wiring base uses an N.P.S.C. threaded plug. Use teflon tape or other thread sealant when inserting the hole plug in the conduit opening to maintain a NEMA Type 4 seal. Tighten hole plug with a 3/8” hex wrench.
- Metric Wiring Base (Catalog No. 2755-NB41) The conduit opening for the metric version requires an O-ring with the hole plug. Place the O-ring on the hole plug, then insert the hole plug in the conduit opening and tighten with a flat blade screwdriver.
Wiring Base Dust Cover To prevent debris from entering the wiring base when a Reader is not installed, slip the wiring base dust cover over the base. The wiring base dust cover is held in place by the stretch fit of the cover itself.
!
4
ATTENTION: The wiring base dust cover is not intended for permanent installation. The wiring base dust cover temporarily protects the wiring base until a Reader is installed.
40062–308–01(A) Copyright 1995 Allen-Bradley Company, Inc. Printed in USA