_______________________________________________________________ MicroBar 9730 - Installation Manual 1.3 - mb9730en.cmd 99/08/19 _______________________________________________________________ --------------------------------------------------------------- Regulatory Statements - added UL (USA and Canada) and NOM (Mexico) certification (IM) --------------------------------------------------------------- [3. Terminal/cash register used in your application] - modified info at start of section (terminal selector / predefined terminal selections) [terminal selector (all terminals)] - renamed command (added "(all terminals)") - modified info [predefined terminal selections] - added new section [predefined terminal selections - keyboard wedge] - moved to new section - modified info [predefined terminal selections - keyboard wedge - standard PC] - renamed (was "IBM PC AT and compatible") - added info [predefined terminal selections - keyboard wedge - IBM 31xx, 32xx, 34xx / - DEC VT 220, 320, 420 / - DEC VT / PC 510 / - Apple / Macintosh / - Hewlett Packard 700/92 / - Wyse 60, 65, 99GT, 120] - added info [predefined terminal selections - RS-232] - moved to new section - modified info [predefined terminal selections - RS-232 - standard RS-232 C (9600, 7, E, 2)] - renamed (was "C (9600, 7, E, 2)") - modified info [custom interface number] - added new section [custom interface number - compose] - renamed (was "interface number selector") - moved to new section [custom interface number - null interface] - moved to new section --------------------------------------------------------------- [4. Output transmission settings] [RS-232 - LRC (longitudinal redundancy check)] - added info --------------------------------------------------------------- [5. Symbologies] [Code 128 / EAN 128] - modified info ("EAN 128" definition) --------------------------------------------------------------- [6. Input devices] - modified drawing (added "dual-pen adaptor" info) (IM) [laser scanners/CCD scanners in laser emulation - activation - port 4] - added info (risk of deactivating the MicroBar and recovery procedure) (moved from "activation") [laser scanners/CCD scanners in laser emulation - activation - port 4 - Intermec Sabre 1550 X05 / other scanners] - modified command name (was "Intermec Sabre 1550 and other scanners") - modified info ("standard interface", connector description) [laser scanners/CCD scanners in laser emulation - activation - port 4 - Intermec Sabre 1550 X01] - modified command name (was "other Intermec scanners") - added info ("Intermec interface", connector description) [laser scanners/CCD scanners in laser emulation - activation - port 4 - Symbol LS 3000 LR only] - modified command name (added "only") [laser scanners/CCD scanners in laser emulation - activation - port 5 - Intermec Sabre 1550 X01] - modified command name (was "Intermec") - modified info/added "Intermec interface" [laser scanners/CCD scanners in laser emulation - activation - port 5 - Intermec Sabre 1550 X05 / other scanners] - modified command name (was "other scanners") - added info ("standard interface", connector description) - moved in front of Symbol command [laser scanners/CCD scanners in laser emulation - activation - port 5 - Symbol LS 3000 LR only] - modified command name (added "only") - moved after Intermec commands [laser scanners/CCD scanners in laser emulation - activation - ports 4 and 5] - removed [RS-232 input devices on port 4] - corrected info ("magstripe readers" only on port 5, not on port 4) --------------------------------------------------------------- [7. Operating settings] [beeps / green indicator LED - note (tone frequency)] - removed "period" info from "high, low, medium" - removed "compose period" - added "compose frequency" (IM) [beeps / green indicator LED - external beep command] - modified info --------------------------------------------------------------- [8. Configuration modes and utilities] [get version info (EPROM software / Smart cable software)] - renamed (was "display EPROM software version") - modified info (text + examples) [flash memory upgrade with RS-232 cable 0-234032-00] - corrected name ("with RS-232 cable 0-234032-00" had disappeared!) --------------------------------------------------------------- [B. Additional preamble/postamble characters - keyboard wedge] [FIELD +] - corrected code (IM) [BACK TAB] - corrected code (IM) [ARROW UP] - corrected code (IM) [FIELD -] - corrected code (IM) --------------------------------------------------------------- [C. Number codes] [6] - corrected code (IM) [End selection] (both codes) - corrected codes (IM) --------------------------------------------------------------- [E. Technical data] - replaced "UBI" by "Intermec" (several occurrences) --------------------------------------------------------------- [INDEX] - added "flash memory, frequency, LRC, predefined, Smart cable, terminal, volume" - removed "EEPROM" --------------------------------------------------------------- _______________________________________________________________ MicroBar 9730 - Installation Manual 1.3 - mb9730en.cmd 99/05/11 _______________________________________________________________ --------------------------------------------------------------- [3. Terminal/cash register used in your application] [interface number selector] - increased range: 100-30000 (was 100-20000) --------------------------------------------------------------- [4. Output transmission settings] [keyboard wedge - control character substitution] - moved from "data reformatting" [keyboard wedge - keyboard remapping] - added [data editing] - added (replaces "data reformatting" in EasySet 3.0) - kept both "data editing" and "data reformatting" (according to EasySet version) in Installation Manual (IM) --------------------------------------------------------------- [6. Input devices] [scales / weighing machines] - added (new "scale solicitation" function) [RS-232 input devices on port 4] - added info on adaptor cable --------------------------------------------------------------- [INDEX] - added "control character, data editing (replaces "data reformatting"), editing, keyboard, keyboard remapping, remapping, scales, scale solicitation, solicitation" --------------------------------------------------------------- _______________________________________________________________ MicroBar 9730 - Installation Manual 1.3 - mb9730en.cmd 99/03/16 _______________________________________________________________ --------------------------------------------------------------- [4. Output transmission settings] [symbology identifier - custom - compose] - modified to allow special wedge characters --------------------------------------------------------------- _______________________________________________________________ MicroBar 9730 - Installation Manual 1.3 - mb9730en.cmd 99/03/01 _______________________________________________________________ --------------------------------------------------------------- [4. Output transmission settings] [preamble - keyboard wedge / RS-232 - compose] - corrected info (max = 10 characters, not 20) [postamble - keyboard wedge / RS-232 - compose] - corrected info (max = 10 characters, not 20) --------------------------------------------------------------- [7. Operating settings] [beeps / green indicator LED - external beep command] - added --------------------------------------------------------------- _______________________________________________________________ MicroBar 9730 - Installation Manual 1.3 - mb9730en.cmd 99/02/10 _______________________________________________________________ --------------------------------------------------------------- [3. Terminal/cash register used in your application] [terminal selector] - added --------------------------------------------------------------- [4. Output transmission settings] [data reformatting - control character substitution] - added --------------------------------------------------------------- [6. Input devices] [laser scanners/CCD scanners in laser emulation - laser trigger management - laser timeout before deactivation - unlimited] - added (new default command, previous default was 2 sec) --------------------------------------------------------------- _______________________________________________________________ MicroBar 9730 - Installation Manual 1.2 - mb9730en.cmd 98/12/21 _______________________________________________________________ --------------------------------------------------------------- [1. Using EasySet] - modified last line of general info on online setup (added "see IM" text) - removed temporarily references to "special download cable" (IM) [online setup with RS-232 cable 0-234032-00] - added title and procedure [online setup with RS-232 cable 0-234032-00 - start EasySet online setup] - modified command name (was "RS-232 online setup mode") - added activation message (cmd) - moved in front of procedure (IM) --------------------------------------------------------------- [3. Terminal / cash register used in your application] [keyboard wedge] - added "connections info" (moved from section 4) - added warning to unplug power supply if switch off PC [RS-232] - added "connections info" (moved from section 4) --------------------------------------------------------------- [4. Output transmission settings] [preamble] - added at first level (moved from "keyboard wedge" and "RS-232") [preamble - keyboard wedge - compose] - added info for ASCII values 01h to 1Fh (wedge PC) [symbology identifier] - added at first level (moved from "keyboard wedge" and "RS-232") [data reformatting] - modified info (added "see IM for full details") - added full details (IM) [postamble] - added at first level (moved from "keyboard wedge" and "RS-232") [postamble - RS-232 - compose] - added info for ASCII values 01h to 1Fh (wedge PC) --------------------------------------------------------------- [5. Symbologies] [Codabar - concatenation] - reorganized, modified command names and info [Code 128/EAN 128 - FNC1 separator character (EAN 128 norms) - GS (ASCII 29) (*)] - added (default command) [Interleaved 2 of 5 - barcode length] - added/corrected info [Interleaved 2 of 5 - barcode length - 1 fixed length = 14 characters (*)] - added new default command [Plessey Code - check digit] - corrected default (= "not transmitted") [Standard 2 of 5 - barcode length] - added/corrected info [Standard 2 of 5 - barcode length - 1 fixed length = 6 characters (*)] - added new default command --------------------------------------------------------------- [6. Input devices] [laser scanners/CCD scanners in laser emulation] - modified section title/info [laser scanners/CCD scanners in laser emulation - activation] - added new title and modified structure for laser scanners on ports 4 and 5 [laser scanners/CCD scanners in laser emulation - activation - port 4 - Intermec Sabre 1550 and other scanners (*)] - modified command name and info (was "other scanners") [laser scanners/CCD scanners in laser emulation - activation - port 4 - other Intermec scanners] - modified command name (was "Intermec") [laser scanners - laser trigger management - CTS trigger] - modified info [laser scanners - marker beam] - removed [laser scanners - autostand mode] - removed [magstripe readers - track separator character - # (ASCII 35) (*)] - added (default command) --------------------------------------------------------------- [8. Configuration modes and utilities] [flash memory upgrade with RS-232 cable 0-234032-00] - removed temporarily references to "special download cable" - added "print out and read" message (displayed in EasySet) --------------------------------------------------------------- [A. ASCII character codes] (IM) [` (60h)] - removed configuration code (character not available for Intermec STC products) --------------------------------------------------------------- [E. Technical data] (IM) [Input/output ports] - added new appendix --------------------------------------------------------------- [INDEX] - added "input port" --------------------------------------------------------------- _______________________________________________________________ MicroBar 9730 - Installation Manual 1.1 - mb9730en.cmd 98/09/25 _______________________________________________________________ --------------------------------------------------------------- [3. Terminal/cash register used in your application] - removed references to terminal list selector (IM) [RS-232] (IM) - modified diagrams (direct RS-232 and dual RS-232) --------------------------------------------------------------- [4. Output transmission settings] [RS-232 - inter-message delay (output to host) - 5000 ms] - corrected datastring [message length information] - added function, modified "transmitted" string info wherever it appears (preamble, input_id, ...) [data reformatting] - moved function to end of section 4 --------------------------------------------------------------- [5. Symbologies] [Interleaved 2 of 5 - barcode length] - corrected title/text [Standard 2 of 5 - barcode length] - corrected title/text --------------------------------------------------------------- [6. Input devices] [RS-232 input devices on port <4/5> - transmission to the host system - compose end-of-message character] - corrected datastring [RS-232 input devices on port <4/5> - special keys interpretation (output to keyboard wedge)] - added new title "single character ASCII value > 7Fh" + changed name of datastring [RS-232 input devices on port 4 - special keys interpretation (output to keyboard wedge)] (IM) - corrected information --------------------------------------------------------------- [8. Configuration modes and utilities] [RS-232 slave mode] - removed --------------------------------------------------------------- [INDEX] - added "data reformatting, message length, special keys interpretation, input port identifier, input devices, magstripe, laser scanner" ----------------------------- END -----------------------------